]> www.pilppa.org Git - linux-2.6-omap-h63xx.git/commitdiff
m68knommu: fix ColdFire 5272 serial baud rates in mcf.c
authorJohn Adamson <jadamson@allen-organ.com>
Fri, 22 Aug 2008 06:43:49 +0000 (16:43 +1000)
committerGreg Ungerer <gerg@uclinux.org>
Tue, 27 Jan 2009 06:42:00 +0000 (16:42 +1000)
I noticed (the hard way) that the mcf.c driver doesn't support the fractional precision register on the MCF5272.  This makes the console dicey at 115200 baud and a system clock of 66.0 MHz.  On the other hand, if your hardware is running at 66.666 MHz, it probably isn't a problem.

Patch submitted by John Adamson <jadamson@allen-organ.com>

Signed-off-by: Greg Ungerer <gerg@uclinux.org>
drivers/serial/mcf.c

index b2001c5b145cb9a0efc8a2a1ef9aec255929cd15..56841fe5f4839bd70d3e917bf32317ada965154e 100644 (file)
@@ -212,10 +212,18 @@ static void mcf_set_termios(struct uart_port *port, struct ktermios *termios,
 {
        unsigned long flags;
        unsigned int baud, baudclk;
+#if defined(CONFIG_M5272)
+       unsigned int baudfr;
+#endif
        unsigned char mr1, mr2;
 
        baud = uart_get_baud_rate(port, termios, old, 0, 230400);
+#if defined(CONFIG_M5272)
+       baudclk = (MCF_BUSCLK / baud) / 32;
+       baudfr = (((MCF_BUSCLK / baud) + 1) / 2) % 16;
+#else
        baudclk = ((MCF_BUSCLK / baud) + 16) / 32;
+#endif
 
        mr1 = MCFUART_MR1_RXIRQRDY | MCFUART_MR1_RXERRCHAR;
        mr2 = 0;
@@ -262,6 +270,9 @@ static void mcf_set_termios(struct uart_port *port, struct ktermios *termios,
        writeb(mr2, port->membase + MCFUART_UMR);
        writeb((baudclk & 0xff00) >> 8, port->membase + MCFUART_UBG1);
        writeb((baudclk & 0xff), port->membase + MCFUART_UBG2);
+#if defined(CONFIG_M5272)
+       writeb((baudfr & 0x0f), port->membase + MCFUART_UFPD);
+#endif
        writeb(MCFUART_UCSR_RXCLKTIMER | MCFUART_UCSR_TXCLKTIMER,
                port->membase + MCFUART_UCSR);
        writeb(MCFUART_UCR_RXENABLE | MCFUART_UCR_TXENABLE,