Impact: avoid spurious lapic timer events on shutdown
The apic timer might be close to firing when it is shutdown. We can
not really disable the timer - we just mask the interrupt. That way we
can get an extra interrupt when it is reenabled. Set the counter to
max on shutdown to avoid this.
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
                v = apic_read(APIC_LVTT);
                v |= (APIC_LVT_MASKED | LOCAL_TIMER_VECTOR);
                apic_write(APIC_LVTT, v);
+               apic_write(APIC_TMICT, 0xffffffff);
                break;
        case CLOCK_EVT_MODE_RESUME:
                /* Nothing to do here */