We get +128 instead of -128 from the DSDT TMPx methods, due to errors when
converting a EC byte return that is a s8 to an ACPI handler return that is
an int.
Fix it once and for all, by clamping acceptable temperature readings from
DSDT TMPx so that anything outside the [-127,+127] range is converted to
TP_EC_THERMAL_TMP_NA (-128).
Signed-off-by: Henrique de Moraes Holschuh <hmh@hmh.eng.br>
Cc: Michael Olbrich <michael.olbrich@gmx.net>
Signed-off-by: Len Brown <len.brown@intel.com>
                        snprintf(tmpi, sizeof(tmpi), "TMP%c", '0' + idx);
                        if (!acpi_evalf(ec_handle, &t, tmpi, "d"))
                                return -EIO;
+                       if (t > 127 || t < -127)
+                               t = TP_EC_THERMAL_TMP_NA;
                        *value = t * 1000;
                        return 0;
                }