There is no association process in IBSS mode - so testing the
association id is not needed.
Signed-off-by: Reinette Chatre <reinette.chatre@intel.com>
Signed-off-by: Tomas Winkler <tomas.winkler@intel.com>
CC: Richard Scherping <richard@scherping.de>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
 #endif
 
        /* drop all data frame if we are not associated */
-       if ((!iwl3945_is_associated(priv) || !priv->assoc_id) &&
+       if ((!iwl3945_is_associated(priv) ||
+            ((priv->iw_mode == IEEE80211_IF_TYPE_STA) && !priv->assoc_id)) &&
            ((fc & IEEE80211_FCTL_FTYPE) == IEEE80211_FTYPE_DATA)) {
                IWL_DEBUG_DROP("Dropping - !iwl3945_is_associated\n");
                goto drop_unlock;
 
        /* drop all data frame if we are not associated */
        if (((fc & IEEE80211_FCTL_FTYPE) == IEEE80211_FTYPE_DATA) &&
           (!iwl4965_is_associated(priv) ||
-           !priv->assoc_id ||
+           ((priv->iw_mode == IEEE80211_IF_TYPE_STA) && !priv->assoc_id) ||
            !priv->assoc_station_added)) {
                IWL_DEBUG_DROP("Dropping - !iwl4965_is_associated\n");
                goto drop_unlock;