The check for an unitialized clock event device triggers, when the local
apic timer is registered as a dummy clock event device for broadcasting.
Preset the multiplicator to avoid a false positive.
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
         */
        if (local_apic_timer_disabled) {
                /* No broadcast on UP ! */
-               if (num_possible_cpus() > 1)
+               if (num_possible_cpus() > 1) {
+                       lapic_clockevent.mult = 1;
                        setup_APIC_timer();
+               }
                return;
        }
 
 
        if (disable_apic_timer) {
                printk(KERN_INFO "Disabling APIC timer\n");
                /* No broadcast on UP ! */
-               if (num_possible_cpus() > 1)
+               if (num_possible_cpus() > 1) {
+                       lapic_clockevent.mult = 1;
                        setup_APIC_timer();
+               }
                return;
        }