Close a small window where a device may be not operational again after senseid
finished and the "same device" check fails due to dev=0000 by checking for dnv
after stsch() by then setting the device to not operational.  (No need to
check for dnv in ccw_device_handle_oper() again since we don't do stsch() into
the subchannel's schib in the meantime and will get a crw anyway if the device
becomes not oper again).
Signed-off-by: Cornelia Huck <cohuck@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
                sch->schib.pmcw.pam &
                sch->schib.pmcw.pom &
                sch->opm;
+       /* Check since device may again have become not operational. */
+       if (!sch->schib.pmcw.dnv)
+               state = DEV_STATE_NOT_OPER;
        if (cdev->private->state == DEV_STATE_DISCONNECTED_SENSE_ID)
                /* Force reprobe on all chpids. */
                old_lpm = 0;