/* flow control */
 #define IXGBE_DEFAULT_FCRTL            0x10000
-#define IXGBE_MIN_FCRTL                              0
+#define IXGBE_MIN_FCRTL                           0x40
 #define IXGBE_MAX_FCRTL                        0x7FF80
 #define IXGBE_DEFAULT_FCRTH            0x20000
-#define IXGBE_MIN_FCRTH                              0
+#define IXGBE_MIN_FCRTH                          0x600
 #define IXGBE_MAX_FCRTH                        0x7FFF0
-#define IXGBE_DEFAULT_FCPAUSE           0x6800  /* may be too long */
+#define IXGBE_DEFAULT_FCPAUSE           0xFFFF
 #define IXGBE_MIN_FCPAUSE                    0
 #define IXGBE_MAX_FCPAUSE               0xFFFF
 
 
        rmcs_reg = IXGBE_READ_REG(hw, IXGBE_RMCS);
        rmcs_reg &= ~(IXGBE_RMCS_TFCE_PRIORITY | IXGBE_RMCS_TFCE_802_3X);
 
+       /*
+        * 10 gig parts do not have a word in the EEPROM to determine the
+        * default flow control setting, so we explicitly set it to full.
+        */
+       if (hw->fc.type == ixgbe_fc_default)
+               hw->fc.type = ixgbe_fc_full;
+
        /*
         * We want to save off the original Flow Control configuration just in
         * case we get disconnected and then reconnected into a different hub
        IXGBE_WRITE_REG(hw, IXGBE_FCTRL, frctl_reg);
        IXGBE_WRITE_REG(hw, IXGBE_RMCS, rmcs_reg);
 
+       /*
+        * Check for invalid software configuration, zeros are completely
+        * invalid for all parameters used past this point, and if we enable
+        * flow control with zero water marks, we blast flow control packets.
+        */
+       if (!hw->fc.low_water || !hw->fc.high_water || !hw->fc.pause_time) {
+               hw_dbg(hw, "Flow control structure initialized incorrectly\n");
+               return IXGBE_ERR_INVALID_LINK_SETTINGS;
+       }
+
        /*
         * We need to set up the Receive Threshold high and low water
         * marks as well as (optionally) enabling the transmission of
 
        adapter->tx_eitr = 1;
 
        /* default flow control settings */
-       hw->fc.original_type = ixgbe_fc_full;
-       hw->fc.type = ixgbe_fc_full;
+       hw->fc.original_type = ixgbe_fc_none;
+       hw->fc.type = ixgbe_fc_none;
+       hw->fc.high_water = IXGBE_DEFAULT_FCRTH;
+       hw->fc.low_water = IXGBE_DEFAULT_FCRTL;
+       hw->fc.pause_time = IXGBE_DEFAULT_FCPAUSE;
+       hw->fc.send_xon = true;
 
        /* select 10G link by default */
        hw->mac.link_mode_select = IXGBE_AUTOC_LMS_10G_LINK_NO_AN;
 
        INIT_WORK(&adapter->reset_task, ixgbe_reset_task);
 
-       /* initialize default flow control settings */
-       hw->fc.original_type = ixgbe_fc_full;
-       hw->fc.type = ixgbe_fc_full;
-       hw->fc.high_water = IXGBE_DEFAULT_FCRTH;
-       hw->fc.low_water = IXGBE_DEFAULT_FCRTL;
-       hw->fc.pause_time = IXGBE_DEFAULT_FCPAUSE;
-
        err = ixgbe_init_interrupt_scheme(adapter);
        if (err)
                goto err_sw_init;