Fix the upper sample rate limit for the double rate mode of the AK4396
to the value from the datasheet.
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Signed-off-by: Jaroslav Kysela <perex@perex.cz>
        value = data->ak4396_ctl2 & ~AK4396_DFS_MASK;
        if (params_rate(params) <= 54000)
                value |= AK4396_DFS_NORMAL;
-       else if (params_rate(params) < 120000)
+       else if (params_rate(params) <= 108000)
                value |= AK4396_DFS_DOUBLE;
        else
                value |= AK4396_DFS_QUAD;
 
        value = data->ak4396_ctl2 & ~AK4396_DFS_MASK;
        if (params_rate(params) <= 54000)
                value |= AK4396_DFS_NORMAL;
-       else if (params_rate(params) < 120000)
+       else if (params_rate(params) <= 108000)
                value |= AK4396_DFS_DOUBLE;
        else
                value |= AK4396_DFS_QUAD;