static int iwl4965_mac_ampdu_action(struct ieee80211_hw *hw,
enum ieee80211_ampdu_mlme_action action,
- const u8 *addr, u16 tid, u16 *ssn)
+ struct ieee80211_sta *sta, u16 tid, u16 *ssn)
{
struct iwl_priv *priv = hw->priv;
DECLARE_MAC_BUF(mac);
IWL_DEBUG_HT("A-MPDU action on addr %s tid %d\n",
- print_mac(mac, addr), tid);
+ print_mac(mac, sta->addr), tid);
if (!(priv->cfg->sku & IWL_SKU_N))
return -EACCES;
switch (action) {
case IEEE80211_AMPDU_RX_START:
IWL_DEBUG_HT("start Rx\n");
- return iwl_rx_agg_start(priv, addr, tid, *ssn);
+ return iwl_rx_agg_start(priv, sta->addr, tid, *ssn);
case IEEE80211_AMPDU_RX_STOP:
IWL_DEBUG_HT("stop Rx\n");
- return iwl_rx_agg_stop(priv, addr, tid);
+ return iwl_rx_agg_stop(priv, sta->addr, tid);
case IEEE80211_AMPDU_TX_START:
IWL_DEBUG_HT("start Tx\n");
- return iwl_tx_agg_start(priv, addr, tid, ssn);
+ return iwl_tx_agg_start(priv, sta->addr, tid, ssn);
case IEEE80211_AMPDU_TX_STOP:
IWL_DEBUG_HT("stop Tx\n");
- return iwl_tx_agg_stop(priv, addr, tid);
+ return iwl_tx_agg_stop(priv, sta->addr, tid);
default:
IWL_DEBUG_HT("unknown\n");
return -EINVAL;