1 menu "SCSI device support"
2
3 config RAID_ATTRS
4         tristate "RAID Transport Class"
5         default n
6         depends on BLOCK
7         ---help---
8           Provides RAID
9
10 config SCSI
11         tristate "SCSI device support"
12         depends on BLOCK
13         select SCSI_DMA if HAS_DMA
14         ---help---
15           If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
16           any other SCSI device under Linux, say Y and make sure that you know
17           the name of your SCSI host adapter (the card inside your computer
18           that "speaks" the SCSI protocol, also called SCSI controller),
19           because you will be asked for it.
20
21           You also need to say Y here if you have a device which speaks
22           the SCSI protocol.  Examples of this include the parallel port
23           version of the IOMEGA ZIP drive, USB storage devices, Fibre
24           Channel, FireWire storage and the IDE-SCSI emulation driver.
25
26           To compile this driver as a module, choose M here and read
27           <file:Documentation/scsi/scsi.txt>.
28           The module will be called scsi_mod.
29
30           However, do not compile this as a module if your root file system
31           (the one containing the directory /) is located on a SCSI device.
32
33 config SCSI_DMA
34         bool
35         default n
36
37 config SCSI_TGT
38         tristate "SCSI target support"
39         depends on SCSI && EXPERIMENTAL
40         ---help---
41           If you want to use SCSI target mode drivers enable this option.
42           If you choose M, the module will be called scsi_tgt.
43
44 config SCSI_NETLINK
45         bool
46         default n
47         select NET
48
49 config SCSI_PROC_FS
50         bool "legacy /proc/scsi/ support"
51         depends on SCSI && PROC_FS
52         default y
53         ---help---
54           This option enables support for the various files in
55           /proc/scsi.  In Linux 2.6 this has been superseded by
56           files in sysfs but many legacy applications rely on this.
57
58           If unsure say Y.
59
60 comment "SCSI support type (disk, tape, CD-ROM)"
61         depends on SCSI
62
63 config BLK_DEV_SD
64         tristate "SCSI disk support"
65         depends on SCSI
66         ---help---
67           If you want to use SCSI hard disks, Fibre Channel disks,
68           Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
69           USB storage or the SCSI or parallel port version of
70           the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
71           the Disk-HOWTO and the Multi-Disk-HOWTO, available from
72           <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
73           CD-ROMs.
74
75           To compile this driver as a module, choose M here and read
76           <file:Documentation/scsi/scsi.txt>.
77           The module will be called sd_mod.
78
79           Do not compile this driver as a module if your root file system
80           (the one containing the directory /) is located on a SCSI disk.
81           In this case, do not compile the driver for your SCSI host adapter
82           (below) as a module either.
83
84 config CHR_DEV_ST
85         tristate "SCSI tape support"
86         depends on SCSI
87         ---help---
88           If you want to use a SCSI tape drive under Linux, say Y and read the
89           SCSI-HOWTO, available from
90           <http://www.tldp.org/docs.html#howto>, and
91           <file:Documentation/scsi/st.txt> in the kernel source.  This is NOT
92           for SCSI CD-ROMs.
93
94           To compile this driver as a module, choose M here and read
95           <file:Documentation/scsi/scsi.txt>. The module will be called st.
96
97 config CHR_DEV_OSST
98         tristate "SCSI OnStream SC-x0 tape support"
99         depends on SCSI
100         ---help---
101           The OnStream SC-x0 SCSI tape drives cannot be driven by the
102           standard st driver, but instead need this special osst driver and
103           use the  /dev/osstX char device nodes (major 206).  Via usb-storage
104           and ide-scsi, you may be able to drive the USB-x0 and DI-x0 drives
105           as well.  Note that there is also a second generation of OnStream
106           tape drives (ADR-x0) that supports the standard SCSI-2 commands for
107           tapes (QIC-157) and can be driven by the standard driver st.
108           For more information, you may have a look at the SCSI-HOWTO
109           <http://www.tldp.org/docs.html#howto>  and
110           <file:Documentation/scsi/osst.txt>  in the kernel source.
111           More info on the OnStream driver may be found on
112           <http://linux1.onstream.nl/test/>
113           Please also have a look at the standard st docu, as most of it
114           applies to osst as well.
115
116           To compile this driver as a module, choose M here and read
117           <file:Documentation/scsi/scsi.txt>. The module will be called osst.
118
119 config BLK_DEV_SR
120         tristate "SCSI CDROM support"
121         depends on SCSI
122         ---help---
123           If you want to use a SCSI or FireWire CD-ROM under Linux,
124           say Y and read the SCSI-HOWTO and the CDROM-HOWTO at
125           <http://www.tldp.org/docs.html#howto>. Also make sure to say
126           Y or M to "ISO 9660 CD-ROM file system support" later.
127
128           To compile this driver as a module, choose M here and read
129           <file:Documentation/scsi/scsi.txt>.
130           The module will be called sr_mod.
131
132 config BLK_DEV_SR_VENDOR
133         bool "Enable vendor-specific extensions (for SCSI CDROM)"
134         depends on BLK_DEV_SR
135         help
136           This enables the usage of vendor specific SCSI commands. This is
137           required to support multisession CDs with old NEC/TOSHIBA cdrom
138           drives (and HP Writers). If you have such a drive and get the first
139           session only, try saying Y here; everybody else says N.
140
141 config CHR_DEV_SG
142         tristate "SCSI generic support"
143         depends on SCSI
144         ---help---
145           If you want to use SCSI scanners, synthesizers or CD-writers or just
146           about anything having "SCSI" in its name other than hard disks,
147           CD-ROMs or tapes, say Y here. These won't be supported by the kernel
148           directly, so you need some additional software which knows how to
149           talk to these devices using the SCSI protocol:
150
151           For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
152           writer software look at Cdrtools
153           (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
154           and for burning a "disk at once": CDRDAO
155           (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
156           quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
157           For other devices, it's possible that you'll have to write the
158           driver software yourself. Please read the file
159           <file:Documentation/scsi/scsi-generic.txt> for more information.
160
161           To compile this driver as a module, choose M here and read
162           <file:Documentation/scsi/scsi.txt>. The module will be called sg.
163
164           If unsure, say N.
165
166 config CHR_DEV_SCH
167         tristate "SCSI media changer support"
168         depends on SCSI
169         ---help---
170           This is a driver for SCSI media changers.  Most common devices are
171           tape libraries and MOD/CDROM jukeboxes.  *Real* jukeboxes, you
172           don't need this for those tiny 6-slot cdrom changers.  Media
173           changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
174           If you have such hardware and want to use it with linux, say Y
175           here.  Check <file:Documentation/scsi/scsi-changer.txt> for details.
176         
177           If you want to compile this as a module ( = code which can be
178           inserted in and removed from the running kernel whenever you want),
179           say M here and read <file:Documentation/kbuild/modules.txt> and
180           <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
181           If unsure, say N.
182         
183
184 comment "Some SCSI devices (e.g. CD jukebox) support multiple LUNs"
185         depends on SCSI
186
187 config SCSI_MULTI_LUN
188         bool "Probe all LUNs on each SCSI device"
189         depends on SCSI
190         help
191           If you have a SCSI device that supports more than one LUN (Logical
192           Unit Number), e.g. a CD jukebox, and only one LUN is detected, you
193           can say Y here to force the SCSI driver to probe for multiple LUNs.
194           A SCSI device with multiple LUNs acts logically like multiple SCSI
195           devices. The vast majority of SCSI devices have only one LUN, and
196           so most people can say N here. The max_luns boot/module parameter 
197           allows to override this setting.
198
199 config SCSI_CONSTANTS
200         bool "Verbose SCSI error reporting (kernel size +=12K)"
201         depends on SCSI
202         help
203           The error messages regarding your SCSI hardware will be easier to
204           understand if you say Y here; it will enlarge your kernel by about
205           12 KB. If in doubt, say Y.
206
207 config SCSI_LOGGING
208         bool "SCSI logging facility"
209         depends on SCSI
210         ---help---
211           This turns on a logging facility that can be used to debug a number
212           of SCSI related problems.
213
214           If you say Y here, no logging output will appear by default, but you
215           can enable logging by saying Y to "/proc file system support" and
216           "Sysctl support" below and executing the command
217
218           echo "scsi log token [level]" > /proc/scsi/scsi
219
220           at boot time after the /proc file system has been mounted.
221
222           There are a number of things that can be used for 'token' (you can
223           find them in the source: <file:drivers/scsi/scsi.c>), and this
224           allows you to select the types of information you want, and the
225           level allows you to select the level of verbosity.
226
227           If you say N here, it may be harder to track down some types of SCSI
228           problems. If you say Y here your kernel will be somewhat larger, but
229           there should be no noticeable performance impact as long as you have
230           logging turned off.
231
232 config SCSI_SCAN_ASYNC
233         bool "Asynchronous SCSI scanning"
234         depends on SCSI
235         help
236           The SCSI subsystem can probe for devices while the rest of the
237           system continues booting, and even probe devices on different
238           busses in parallel, leading to a significant speed-up.
239
240           If you have built SCSI as modules, enabling this option can
241           be a problem as the devices may not have been found by the
242           time your system expects them to have been.  You can load the
243           scsi_wait_scan module to ensure that all scans have completed.
244           If you build your SCSI drivers into the kernel, then everything
245           will work fine if you say Y here.
246
247           You can override this choice by specifying "scsi_mod.scan=sync"
248           or async on the kernel's command line.
249
250 config SCSI_WAIT_SCAN
251         tristate
252         default m
253         depends on SCSI
254         depends on MODULES
255
256 menu "SCSI Transports"
257         depends on SCSI
258
259 config SCSI_SPI_ATTRS
260         tristate "Parallel SCSI (SPI) Transport Attributes"
261         depends on SCSI
262         help
263           If you wish to export transport-specific information about
264           each attached SCSI device to sysfs, say Y.  Otherwise, say N.
265
266 config SCSI_FC_ATTRS
267         tristate "FiberChannel Transport Attributes"
268         depends on SCSI
269         select SCSI_NETLINK
270         help
271           If you wish to export transport-specific information about
272           each attached FiberChannel device to sysfs, say Y.
273           Otherwise, say N.
274
275 config SCSI_FC_TGT_ATTRS
276         bool "SCSI target support for FiberChannel Transport Attributes"
277         depends on SCSI_FC_ATTRS
278         depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
279         help
280                 If you want to use SCSI target mode drivers enable this option.
281
282 config SCSI_ISCSI_ATTRS
283         tristate "iSCSI Transport Attributes"
284         depends on SCSI && NET
285         help
286           If you wish to export transport-specific information about
287           each attached iSCSI device to sysfs, say Y.
288           Otherwise, say N.
289
290 config SCSI_SAS_ATTRS
291         tristate "SAS Transport Attributes"
292         depends on SCSI && BLK_DEV_BSG
293         help
294           If you wish to export transport-specific information about
295           each attached SAS device to sysfs, say Y.
296
297 source "drivers/scsi/libsas/Kconfig"
298
299 config SCSI_SRP_ATTRS
300         tristate "SRP Transport Attributes"
301         depends on SCSI
302         help
303           If you wish to export transport-specific information about
304           each attached SRP device to sysfs, say Y.
305
306 config SCSI_SRP_TGT_ATTRS
307         bool "SCSI target support for SRP Transport Attributes"
308         depends on SCSI_SRP_ATTRS
309         depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
310         help
311                 If you want to use SCSI target mode drivers enable this option.
312
313 endmenu
314
315 menuconfig SCSI_LOWLEVEL
316         bool "SCSI low-level drivers"
317         depends on SCSI!=n
318         default y
319
320 if SCSI_LOWLEVEL
321
322 config ISCSI_TCP
323         tristate "iSCSI Initiator over TCP/IP"
324         depends on SCSI && INET
325         select CRYPTO
326         select CRYPTO_MD5
327         select CRYPTO_CRC32C
328         select SCSI_ISCSI_ATTRS
329         help
330          The iSCSI Driver provides a host with the ability to access storage
331          through an IP network. The driver uses the iSCSI protocol to transport
332          SCSI requests and responses over a TCP/IP network between the host
333          (the "initiator") and "targets".  Architecturally, the iSCSI driver
334          combines with the host's TCP/IP stack, network drivers, and Network
335          Interface Card (NIC) to provide the same functions as a SCSI or a
336          Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
337
338          To compile this driver as a module, choose M here: the
339          module will be called iscsi_tcp.
340
341          The userspace component needed to initialize the driver, documentation,
342          and sample configuration files can be found here:
343
344          http://open-iscsi.org
345
346 config SGIWD93_SCSI
347         tristate "SGI WD93C93 SCSI Driver"
348         depends on SGI_HAS_WD93 && SCSI
349         help
350           If you have a Western Digital WD93 SCSI controller on
351           an SGI MIPS system, say Y.  Otherwise, say N.
352
353 config BLK_DEV_3W_XXXX_RAID
354         tristate "3ware 5/6/7/8xxx ATA-RAID support"
355         depends on PCI && SCSI
356         help
357           3ware is the only hardware ATA-Raid product in Linux to date.
358           This card is 2,4, or 8 channel master mode support only.
359           SCSI support required!!!
360
361           <http://www.3ware.com/>
362
363           Please read the comments at the top of
364           <file:drivers/scsi/3w-xxxx.c>.
365
366 config SCSI_3W_9XXX
367         tristate "3ware 9xxx SATA-RAID support"
368         depends on PCI && SCSI
369         help
370           This driver supports the 9000 series 3ware SATA-RAID cards.
371
372           <http://www.amcc.com>
373
374           Please read the comments at the top of
375           <file:drivers/scsi/3w-9xxx.c>.
376
377 config SCSI_7000FASST
378         tristate "7000FASST SCSI support"
379         depends on ISA && SCSI && ISA_DMA_API
380         select CHECK_SIGNATURE
381         help
382           This driver supports the Western Digital 7000 SCSI host adapter
383           family.  Some information is in the source:
384           <file:drivers/scsi/wd7000.c>.
385
386           To compile this driver as a module, choose M here: the
387           module will be called wd7000.
388
389 config SCSI_ACARD
390         tristate "ACARD SCSI support"
391         depends on PCI && SCSI
392         help
393           This driver supports the ACARD SCSI host adapter.
394           Support Chip <ATP870 ATP876 ATP880 ATP885>
395           To compile this driver as a module, choose M here: the
396           module will be called atp870u.
397
398 config SCSI_AHA152X
399         tristate "Adaptec AHA152X/2825 support"
400         depends on ISA && SCSI && !64BIT
401         select SCSI_SPI_ATTRS
402         select CHECK_SIGNATURE
403         ---help---
404           This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
405           SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
406           must be manually specified in this case.
407
408           It is explained in section 3.3 of the SCSI-HOWTO, available from
409           <http://www.tldp.org/docs.html#howto>. You might also want to
410           read the file <file:Documentation/scsi/aha152x.txt>.
411
412           To compile this driver as a module, choose M here: the
413           module will be called aha152x.
414
415 config SCSI_AHA1542
416         tristate "Adaptec AHA1542 support"
417         depends on ISA && SCSI && ISA_DMA_API
418         ---help---
419           This is support for a SCSI host adapter.  It is explained in section
420           3.4 of the SCSI-HOWTO, available from
421           <http://www.tldp.org/docs.html#howto>.  Note that Trantor was
422           purchased by Adaptec, and some former Trantor products are being
423           sold under the Adaptec name.  If it doesn't work out of the box, you
424           may have to change some settings in <file:drivers/scsi/aha1542.h>.
425
426           To compile this driver as a module, choose M here: the
427           module will be called aha1542.
428
429 config SCSI_AHA1740
430         tristate "Adaptec AHA1740 support"
431         depends on EISA && SCSI
432         ---help---
433           This is support for a SCSI host adapter.  It is explained in section
434           3.5 of the SCSI-HOWTO, available from
435           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
436           of the box, you may have to change some settings in
437           <file:drivers/scsi/aha1740.h>.
438
439           To compile this driver as a module, choose M here: the
440           module will be called aha1740.
441
442 config SCSI_AACRAID
443         tristate "Adaptec AACRAID support"
444         depends on SCSI && PCI
445         help
446           This driver supports a variety of Dell, HP, Adaptec, IBM and
447           ICP storage products. For a list of supported products, refer
448           to <file:Documentation/scsi/aacraid.txt>.
449
450           To compile this driver as a module, choose M here: the module
451           will be called aacraid.
452
453
454 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
455
456 config SCSI_AIC7XXX_OLD
457         tristate "Adaptec AIC7xxx support (old driver)"
458         depends on (ISA || EISA || PCI ) && SCSI
459         help
460           WARNING This driver is an older aic7xxx driver and is no longer
461           under active development.  Adaptec, Inc. is writing a new driver to
462           take the place of this one, and it is recommended that whenever
463           possible, people should use the new Adaptec written driver instead
464           of this one.  This driver will eventually be phased out entirely.
465
466           This is support for the various aic7xxx based Adaptec SCSI
467           controllers. These include the 274x EISA cards; 284x VLB cards;
468           2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
469           motherboard based SCSI controllers from Adaptec. It does not support
470           the AAA-13x RAID controllers from Adaptec, nor will it likely ever
471           support them. It does not support the 2920 cards from Adaptec that
472           use the Future Domain SCSI controller chip. For those cards, you
473           need the "Future Domain 16xx SCSI support" driver.
474
475           In general, if the controller is based on an Adaptec SCSI controller
476           chip from the aic777x series or the aic78xx series, this driver
477           should work. The only exception is the 7810 which is specifically
478           not supported (that's the RAID controller chip on the AAA-13x
479           cards).
480
481           Note that the AHA2920 SCSI host adapter is *not* supported by this
482           driver; choose "Future Domain 16xx SCSI support" instead if you have
483           one of those.
484
485           Information on the configuration options for this controller can be
486           found by checking the help file for each of the available
487           configuration options. You should read
488           <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
489           contacting the maintainer with any questions.  The SCSI-HOWTO,
490           available from <http://www.tldp.org/docs.html#howto>, can also
491           be of great help.
492
493           To compile this driver as a module, choose M here: the
494           module will be called aic7xxx_old.
495
496 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
497 source "drivers/scsi/aic94xx/Kconfig"
498
499 # All the I2O code and drivers do not seem to be 64bit safe.
500 config SCSI_DPT_I2O
501         tristate "Adaptec I2O RAID support "
502         depends on !64BIT && SCSI && PCI && VIRT_TO_BUS
503         help
504           This driver supports all of Adaptec's I2O based RAID controllers as 
505           well as the DPT SmartRaid V cards.  This is an Adaptec maintained
506           driver by Deanna Bonds.  See <file:Documentation/scsi/dpti.txt>.
507
508           To compile this driver as a module, choose M here: the
509           module will be called dpt_i2o.
510
511 config SCSI_ADVANSYS
512         tristate "AdvanSys SCSI support"
513         depends on SCSI && VIRT_TO_BUS
514         depends on ISA || EISA || PCI
515         help
516           This is a driver for all SCSI host adapters manufactured by
517           AdvanSys. It is documented in the kernel source in
518           <file:drivers/scsi/advansys.c>.
519
520           To compile this driver as a module, choose M here: the
521           module will be called advansys.
522
523 config SCSI_IN2000
524         tristate "Always IN2000 SCSI support"
525         depends on ISA && SCSI
526         help
527           This is support for an ISA bus SCSI host adapter.  You'll find more
528           information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
529           out of the box, you may have to change the jumpers for IRQ or
530           address selection.
531
532           To compile this driver as a module, choose M here: the
533           module will be called in2000.
534
535 config SCSI_ARCMSR
536         tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
537         depends on PCI && SCSI
538         help
539           This driver supports all of ARECA's SATA/SAS RAID controller cards.
540           This is an ARECA-maintained driver by Erich Chen.
541           If you have any problems, please mail to: <erich@areca.com.tw>.
542           Areca supports Linux RAID config tools.
543           Please link <http://www.areca.com.tw>
544
545           To compile this driver as a module, choose M here: the
546           module will be called arcmsr (modprobe arcmsr).
547
548 config SCSI_ARCMSR_AER
549         bool "Enable PCI Error Recovery Capability in Areca Driver(ARCMSR)"
550         depends on SCSI_ARCMSR && PCIEAER
551         default n
552         help
553           The advanced error reporting(AER) capability is "NOT" provided by
554           ARC1200/1201/1202 SATA RAID controllers cards.
555           If your card is one of ARC1200/1201/1202, please use the default setting, n.
556           If your card is other models, you could pick it
557           on condition that the kernel version is greater than 2.6.19.
558           This function is maintained driver by Nick Cheng. If you have any
559           problems or suggestion, you are welcome to contact with <nick.cheng@areca.com.tw>.
560           To enable this function, choose Y here.
561
562 source "drivers/scsi/megaraid/Kconfig.megaraid"
563
564 config SCSI_HPTIOP
565         tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
566         depends on SCSI && PCI
567         help
568           This option enables support for HighPoint RocketRAID 3xxx/4xxx
569           controllers.
570
571           To compile this driver as a module, choose M here; the module
572           will be called hptiop. If unsure, say N.
573
574 config SCSI_BUSLOGIC
575         tristate "BusLogic SCSI support"
576         depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
577         ---help---
578           This is support for BusLogic MultiMaster and FlashPoint SCSI Host
579           Adapters. Consult the SCSI-HOWTO, available from
580           <http://www.tldp.org/docs.html#howto>, and the files
581           <file:Documentation/scsi/BusLogic.txt> and
582           <file:Documentation/scsi/FlashPoint.txt> for more information.
583
584           To compile this driver as a module, choose M here: the
585           module will be called BusLogic.
586
587 config SCSI_OMIT_FLASHPOINT
588         bool "Omit FlashPoint support"
589         depends on SCSI_BUSLOGIC
590         help
591           This option allows you to omit the FlashPoint support from the
592           BusLogic SCSI driver. The FlashPoint SCCB Manager code is
593           substantial, so users of MultiMaster Host Adapters may wish to omit
594           it.
595
596 config SCSI_DMX3191D
597         tristate "DMX3191D SCSI support"
598         depends on PCI && SCSI
599         select SCSI_SPI_ATTRS
600         help
601           This is support for Domex DMX3191D SCSI Host Adapters.
602
603           To compile this driver as a module, choose M here: the
604           module will be called dmx3191d.
605
606 config SCSI_DTC3280
607         tristate "DTC3180/3280 SCSI support"
608         depends on ISA && SCSI
609         select SCSI_SPI_ATTRS
610         select CHECK_SIGNATURE
611         help
612           This is support for DTC 3180/3280 SCSI Host Adapters.  Please read
613           the SCSI-HOWTO, available from
614           <http://www.tldp.org/docs.html#howto>, and the file
615           <file:Documentation/scsi/dtc3x80.txt>.
616
617           To compile this driver as a module, choose M here: the
618           module will be called dtc.
619
620 config SCSI_EATA
621         tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
622         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
623         ---help---
624           This driver supports all EATA/DMA-compliant SCSI host adapters.  DPT
625           ISA and all EISA I/O addresses are probed looking for the "EATA"
626           signature. The addresses of all the PCI SCSI controllers reported
627           by the PCI subsystem are probed as well.
628
629           You want to read the start of <file:drivers/scsi/eata.c> and the
630           SCSI-HOWTO, available from
631           <http://www.tldp.org/docs.html#howto>.
632
633           To compile this driver as a module, choose M here: the
634           module will be called eata.
635
636 config SCSI_EATA_TAGGED_QUEUE
637         bool "enable tagged command queueing"
638         depends on SCSI_EATA
639         help
640           This is a feature of SCSI-2 which improves performance: the host
641           adapter can send several SCSI commands to a device's queue even if
642           previous commands haven't finished yet.
643           This is equivalent to the "eata=tc:y" boot option.
644
645 config SCSI_EATA_LINKED_COMMANDS
646         bool "enable elevator sorting"
647         depends on SCSI_EATA
648         help
649           This option enables elevator sorting for all probed SCSI disks and
650           CD-ROMs. It definitely reduces the average seek distance when doing
651           random seeks, but this does not necessarily result in a noticeable
652           performance improvement: your mileage may vary...
653           This is equivalent to the "eata=lc:y" boot option.
654
655 config SCSI_EATA_MAX_TAGS
656         int "maximum number of queued commands"
657         depends on SCSI_EATA
658         default "16"
659         help
660           This specifies how many SCSI commands can be maximally queued for
661           each probed SCSI device. You should reduce the default value of 16
662           only if you have disks with buggy or limited tagged command support.
663           Minimum is 2 and maximum is 62. This value is also the window size
664           used by the elevator sorting option above. The effective value used
665           by the driver for each probed SCSI device is reported at boot time.
666           This is equivalent to the "eata=mq:8" boot option.
667
668 config SCSI_EATA_PIO
669         tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
670         depends on (ISA || EISA || PCI) && SCSI && BROKEN
671         ---help---
672           This driver supports all EATA-PIO protocol compliant SCSI Host
673           Adapters like the DPT PM2001 and the PM2012A.  EATA-DMA compliant
674           host adapters could also use this driver but are discouraged from
675           doing so, since this driver only supports hard disks and lacks
676           numerous features.  You might want to have a look at the SCSI-HOWTO,
677           available from <http://www.tldp.org/docs.html#howto>.
678
679           To compile this driver as a module, choose M here: the
680           module will be called eata_pio.
681
682 config SCSI_FUTURE_DOMAIN
683         tristate "Future Domain 16xx SCSI/AHA-2920A support"
684         depends on (ISA || PCI) && SCSI
685         select CHECK_SIGNATURE
686         ---help---
687           This is support for Future Domain's 16-bit SCSI host adapters
688           (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
689           other adapters based on the Future Domain chipsets (Quantum
690           ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
691           It is explained in section 3.7 of the SCSI-HOWTO, available from
692           <http://www.tldp.org/docs.html#howto>.
693
694           NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
695           and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
696           controller support"). This Future Domain driver works with the older
697           Adaptec AHA-2920A boards with a Future Domain chip on them.
698
699           To compile this driver as a module, choose M here: the
700           module will be called fdomain.
701
702 config SCSI_FD_MCS
703         tristate "Future Domain MCS-600/700 SCSI support"
704         depends on MCA_LEGACY && SCSI
705         ---help---
706           This is support for Future Domain MCS 600/700 MCA SCSI adapters.
707           Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
708           is identical to the MCS 700 and hence also supported by this driver.
709           This driver also supports the Reply SB16/SCSI card (the SCSI part).
710           It supports multiple adapters in the same system.
711
712           To compile this driver as a module, choose M here: the
713           module will be called fd_mcs.
714
715 config SCSI_GDTH
716         tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
717         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API && PCI_LEGACY
718         ---help---
719           Formerly called GDT SCSI Disk Array Controller Support.
720
721           This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI) 
722           manufactured by Intel Corporation/ICP vortex GmbH. It is documented
723           in the kernel source in <file:drivers/scsi/gdth.c> and
724           <file:drivers/scsi/gdth.h>.
725
726           To compile this driver as a module, choose M here: the
727           module will be called gdth.
728
729 config SCSI_GENERIC_NCR5380
730         tristate "Generic NCR5380/53c400 SCSI PIO support"
731         depends on ISA && SCSI
732         select SCSI_SPI_ATTRS
733         ---help---
734           This is a driver for the old NCR 53c80 series of SCSI controllers
735           on boards using PIO. Most boards such as the Trantor T130 fit this
736           category, along with a large number of ISA 8bit controllers shipped
737           for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
738           you should select the specific driver for that card rather than
739           generic 5380 support.
740
741           It is explained in section 3.8 of the SCSI-HOWTO, available from
742           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
743           of the box, you may have to change some settings in
744           <file:drivers/scsi/g_NCR5380.h>.
745
746           To compile this driver as a module, choose M here: the
747           module will be called g_NCR5380.
748
749 config SCSI_GENERIC_NCR5380_MMIO
750         tristate "Generic NCR5380/53c400 SCSI MMIO support"
751         depends on ISA && SCSI
752         select SCSI_SPI_ATTRS
753         ---help---
754           This is a driver for the old NCR 53c80 series of SCSI controllers
755           on boards using memory mapped I/O. 
756           It is explained in section 3.8 of the SCSI-HOWTO, available from
757           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
758           of the box, you may have to change some settings in
759           <file:drivers/scsi/g_NCR5380.h>.
760
761           To compile this driver as a module, choose M here: the
762           module will be called g_NCR5380_mmio.
763
764 config SCSI_GENERIC_NCR53C400
765         bool "Enable NCR53c400 extensions"
766         depends on SCSI_GENERIC_NCR5380
767         help
768           This enables certain optimizations for the NCR53c400 SCSI cards.
769           You might as well try it out.  Note that this driver will only probe
770           for the Trantor T130B in its default configuration; you might have
771           to pass a command line option to the kernel at boot time if it does
772           not detect your card.  See the file
773           <file:Documentation/scsi/g_NCR5380.txt> for details.
774
775 config SCSI_IBMMCA
776         tristate "IBMMCA SCSI support"
777         depends on MCA && SCSI
778         ---help---
779           This is support for the IBM SCSI adapter found in many of the PS/2
780           series computers.  These machines have an MCA bus, so you need to
781           answer Y to "MCA support" as well and read
782           <file:Documentation/mca.txt>.
783
784           If the adapter isn't found during boot (a common problem for models
785           56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
786           option, where <pun> is the id of the SCSI subsystem (usually 7, but
787           if that doesn't work check your reference diskette).  Owners of
788           model 95 with a LED-matrix-display can in addition activate some
789           activity info like under OS/2, but more informative, by setting
790           'ibmmcascsi=display' as an additional kernel parameter.  Try "man
791           bootparam" or see the documentation of your boot loader about how to
792           pass options to the kernel.
793
794           To compile this driver as a module, choose M here: the
795           module will be called ibmmca.
796
797 config IBMMCA_SCSI_ORDER_STANDARD
798         bool "Standard SCSI-order"
799         depends on SCSI_IBMMCA
800         ---help---
801           In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
802           are assigned to the drive letters, starting with the lowest SCSI-id
803           (physical number -- pun) to be drive C:, as seen from DOS and
804           similar operating systems. When looking into papers describing the
805           ANSI-SCSI-standard, this assignment of drives appears to be wrong.
806           The SCSI-standard follows a hardware-hierarchy which says that id 7
807           has the highest priority and id 0 the lowest. Therefore, the host
808           adapters are still today everywhere placed as SCSI-id 7 by default.
809           In the SCSI-standard, the drive letters express the priority of the
810           disk. C: should be the hard disk, or a partition on it, with the
811           highest priority. This must therefore be the disk with the highest
812           SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
813           original definition of the SCSI-standard as also industrial- and
814           process-control-machines, like VME-CPUs running under realtime-OSes
815           (e.g. LynxOS, OS9) do.
816
817           If you like to run Linux on your MCA-machine with the same
818           assignment of hard disks as seen from e.g. DOS or OS/2 on your
819           machine, which is in addition conformant to the SCSI-standard, you
820           must say Y here. This is also necessary for MCA-Linux users who want
821           to keep downward compatibility to older releases of the
822           IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
823           June 1997).
824
825           If you like to have the lowest SCSI-id assigned as drive C:, as
826           modern SCSI-BIOSes do, which does not conform to the standard, but
827           is widespread and common in the PC-world of today, you must say N
828           here. If unsure, say Y.
829
830 config IBMMCA_SCSI_DEV_RESET
831         bool "Reset SCSI-devices at boottime"
832         depends on SCSI_IBMMCA
833         ---help---
834           By default, SCSI-devices are reset when the machine is powered on.
835           However, some devices exist, like special-control-devices,
836           SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
837           not reset when switched on. If you say Y here, each device connected
838           to your SCSI-bus will be issued a reset-command after it has been
839           probed, while the kernel is booting. This may cause problems with
840           more modern devices, like hard disks, which do not appreciate these
841           reset commands, and can cause your system to hang. So say Y only if
842           you know that one of your older devices needs it; N is the safe
843           answer.
844
845 config SCSI_IPS
846         tristate "IBM ServeRAID support"
847         depends on PCI && SCSI
848         ---help---
849           This is support for the IBM ServeRAID hardware RAID controllers.
850           See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
851           for more information.  If this driver does not work correctly
852           without modification please contact the author by email at
853           <ipslinux@adaptec.com>.
854
855           To compile this driver as a module, choose M here: the
856           module will be called ips.
857
858 config SCSI_IBMVSCSI
859         tristate "IBM Virtual SCSI support"
860         depends on PPC_PSERIES || PPC_ISERIES
861         select SCSI_SRP_ATTRS
862         help
863           This is the IBM POWER Virtual SCSI Client
864
865           To compile this driver as a module, choose M here: the
866           module will be called ibmvscsic.
867
868 config SCSI_IBMVSCSIS
869         tristate "IBM Virtual SCSI Server support"
870         depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
871         help
872           This is the SRP target driver for IBM pSeries virtual environments.
873
874           The userspace component needed to initialize the driver and
875           documentation can be found:
876
877           http://stgt.berlios.de/
878
879           To compile this driver as a module, choose M here: the
880           module will be called ibmvstgt.
881
882 config SCSI_INITIO
883         tristate "Initio 9100U(W) support"
884         depends on PCI && SCSI
885         help
886           This is support for the Initio 91XXU(W) SCSI host adapter.  Please
887           read the SCSI-HOWTO, available from
888           <http://www.tldp.org/docs.html#howto>.
889
890           To compile this driver as a module, choose M here: the
891           module will be called initio.
892
893 config SCSI_INIA100
894         tristate "Initio INI-A100U2W support"
895         depends on PCI && SCSI
896         help
897           This is support for the Initio INI-A100U2W SCSI host adapter.
898           Please read the SCSI-HOWTO, available from
899           <http://www.tldp.org/docs.html#howto>.
900
901           To compile this driver as a module, choose M here: the
902           module will be called a100u2w.
903
904 config SCSI_PPA
905         tristate "IOMEGA parallel port (ppa - older drives)"
906         depends on SCSI && PARPORT_PC
907         ---help---
908           This driver supports older versions of IOMEGA's parallel port ZIP
909           drive (a 100 MB removable media device).
910
911           Note that you can say N here if you have the SCSI version of the ZIP
912           drive: it will be supported automatically if you said Y to the
913           generic "SCSI disk support", above.
914
915           If you have the ZIP Plus drive or a more recent parallel port ZIP
916           drive (if the supplied cable with the drive is labeled "AutoDetect")
917           then you should say N here and Y to "IOMEGA parallel port (imm -
918           newer drives)", below.
919
920           For more information about this driver and how to use it you should
921           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
922           the SCSI-HOWTO, which is available from
923           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
924           you will still be able to use the parallel port for other tasks,
925           such as a printer; it is safe to compile both drivers into the
926           kernel.
927
928           To compile this driver as a module, choose M here: the
929           module will be called ppa.
930
931 config SCSI_IMM
932         tristate "IOMEGA parallel port (imm - newer drives)"
933         depends on SCSI && PARPORT_PC
934         ---help---
935           This driver supports newer versions of IOMEGA's parallel port ZIP
936           drive (a 100 MB removable media device).
937
938           Note that you can say N here if you have the SCSI version of the ZIP
939           drive: it will be supported automatically if you said Y to the
940           generic "SCSI disk support", above.
941
942           If you have the ZIP Plus drive or a more recent parallel port ZIP
943           drive (if the supplied cable with the drive is labeled "AutoDetect")
944           then you should say Y here; if you have an older ZIP drive, say N
945           here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
946
947           For more information about this driver and how to use it you should
948           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
949           the SCSI-HOWTO, which is available from
950           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
951           you will still be able to use the parallel port for other tasks,
952           such as a printer; it is safe to compile both drivers into the
953           kernel.
954
955           To compile this driver as a module, choose M here: the
956           module will be called imm.
957
958 config SCSI_IZIP_EPP16
959         bool "ppa/imm option - Use slow (but safe) EPP-16"
960         depends on SCSI_PPA || SCSI_IMM
961         ---help---
962           EPP (Enhanced Parallel Port) is a standard for parallel ports which
963           allows them to act as expansion buses that can handle up to 64
964           peripheral devices.
965
966           Some parallel port chipsets are slower than their motherboard, and
967           so we have to control the state of the chipset's FIFO queue every
968           now and then to avoid data loss. This will be done if you say Y
969           here.
970
971           Generally, saying Y is the safe option and slows things down a bit.
972
973 config SCSI_IZIP_SLOW_CTR
974         bool "ppa/imm option - Assume slow parport control register"
975         depends on SCSI_PPA || SCSI_IMM
976         help
977           Some parallel ports are known to have excessive delays between
978           changing the parallel port control register and good data being
979           available on the parallel port data/status register. This option
980           forces a small delay (1.0 usec to be exact) after changing the
981           control register to let things settle out. Enabling this option may
982           result in a big drop in performance but some very old parallel ports
983           (found in 386 vintage machines) will not work properly.
984
985           Generally, saying N is fine.
986
987 config SCSI_NCR53C406A
988         tristate "NCR53c406a SCSI support"
989         depends on ISA && SCSI
990         help
991           This is support for the NCR53c406a SCSI host adapter.  For user
992           configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
993           in the kernel source.  Also read the SCSI-HOWTO, available from
994           <http://www.tldp.org/docs.html#howto>.
995
996           To compile this driver as a module, choose M here: the
997           module will be called NCR53c406.
998
999 config SCSI_NCR_D700
1000         tristate "NCR Dual 700 MCA SCSI support"
1001         depends on MCA && SCSI
1002         select SCSI_SPI_ATTRS
1003         help
1004           This is a driver for the MicroChannel Dual 700 card produced by
1005           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1006           tries to negotiate sync and uses tag command queueing.
1007
1008           Unless you have an NCR manufactured machine, the chances are that
1009           you do not have this SCSI card, so say N.
1010
1011 config SCSI_LASI700
1012         tristate "HP Lasi SCSI support for 53c700/710"
1013         depends on GSC && SCSI
1014         select SCSI_SPI_ATTRS
1015         help
1016           This is a driver for the SCSI controller in the Lasi chip found in
1017           many PA-RISC workstations & servers.  If you do not know whether you
1018           have a Lasi chip, it is safe to say "Y" here.
1019
1020 config SCSI_SNI_53C710
1021         tristate "SNI RM SCSI support for 53c710"
1022         depends on SNI_RM && SCSI
1023         select SCSI_SPI_ATTRS
1024         select 53C700_LE_ON_BE
1025         help
1026           This is a driver for the onboard SCSI controller found in older
1027           SNI RM workstations & servers.
1028
1029 config 53C700_LE_ON_BE
1030         bool
1031         depends on SCSI_LASI700
1032         default y
1033
1034 config SCSI_STEX
1035         tristate "Promise SuperTrak EX Series support"
1036         depends on PCI && SCSI
1037         ---help---
1038           This driver supports Promise SuperTrak EX series storage controllers.
1039
1040           Promise provides Linux RAID configuration utility for these
1041           controllers. Please visit <http://www.promise.com> to download.
1042
1043           To compile this driver as a module, choose M here: the
1044           module will be called stex.
1045
1046 config 53C700_BE_BUS
1047         bool
1048         depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
1049         default y
1050
1051 config SCSI_SYM53C8XX_2
1052         tristate "SYM53C8XX Version 2 SCSI support"
1053         depends on PCI && SCSI
1054         select SCSI_SPI_ATTRS
1055         ---help---
1056           This driver supports the whole NCR53C8XX/SYM53C8XX family of
1057           PCI-SCSI controllers.  It also supports the subset of LSI53C10XX
1058           Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1059           language.  It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1060           controllers; you need to use the Fusion MPT driver for that.
1061
1062           Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1063           information.
1064
1065 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1066         int "DMA addressing mode"
1067         depends on SCSI_SYM53C8XX_2
1068         default "1"
1069         ---help---
1070           This option only applies to PCI-SCSI chips that are PCI DAC
1071           capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1072
1073           When set to 0, the driver will program the chip to only perform
1074           32-bit DMA.  When set to 1, the chip will be able to perform DMA
1075           to addresses up to 1TB.  When set to 2, the driver supports the
1076           full 64-bit DMA address range, but can only address 16 segments
1077           of 4 GB each.  This limits the total addressable range to 64 GB.
1078
1079           Most machines with less than 4GB of memory should use a setting
1080           of 0 for best performance.  If your machine has 4GB of memory
1081           or more, you should set this option to 1 (the default).
1082
1083           The still experimental value 2 (64 bit DMA addressing with 16
1084           x 4GB segments limitation) can be used on systems that require
1085           PCI address bits past bit 39 to be set for the addressing of
1086           memory using PCI DAC cycles.
1087
1088 config SCSI_SYM53C8XX_DEFAULT_TAGS
1089         int "Default tagged command queue depth"
1090         depends on SCSI_SYM53C8XX_2
1091         default "16"
1092         help
1093           This is the default value of the command queue depth the
1094           driver will announce to the generic SCSI layer for devices
1095           that support tagged command queueing. This value can be changed
1096           from the boot command line.  This is a soft limit that cannot
1097           exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1098
1099 config SCSI_SYM53C8XX_MAX_TAGS
1100         int "Maximum number of queued commands"
1101         depends on SCSI_SYM53C8XX_2
1102         default "64"
1103         help
1104           This option allows you to specify the maximum number of commands
1105           that can be queued to any device, when tagged command queuing is
1106           possible. The driver supports up to 256 queued commands per device.
1107           This value is used as a compiled-in hard limit.
1108
1109 config SCSI_SYM53C8XX_MMIO
1110         bool "Use memory mapped IO"
1111         depends on SCSI_SYM53C8XX_2
1112         default y
1113         help
1114           Memory mapped IO is faster than Port IO.  Most people should
1115           answer Y here, but some machines may have problems.  If you have
1116           to answer N here, please report the problem to the maintainer.
1117
1118 config SCSI_IPR
1119         tristate "IBM Power Linux RAID adapter support"
1120         depends on PCI && SCSI && ATA
1121         select FW_LOADER
1122         ---help---
1123           This driver supports the IBM Power Linux family RAID adapters.
1124           This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1125           as IBM iSeries 5702, 5703, 5709, and 570A.
1126
1127 config SCSI_IPR_TRACE
1128         bool "enable driver internal trace"
1129         depends on SCSI_IPR
1130         default y
1131         help
1132           If you say Y here, the driver will trace all commands issued
1133           to the adapter. Performance impact is minimal. Trace can be
1134           dumped using /sys/bus/class/scsi_host/hostXX/trace.
1135
1136 config SCSI_IPR_DUMP
1137         bool "enable adapter dump support"
1138         depends on SCSI_IPR
1139         default y
1140         help
1141           If you say Y here, the driver will support adapter crash dump.
1142           If you enable this support, the iprdump daemon can be used
1143           to capture adapter failure analysis information.
1144
1145 config SCSI_ZALON
1146         tristate "Zalon SCSI support"
1147         depends on GSC && SCSI
1148         select SCSI_SPI_ATTRS
1149         help
1150           The Zalon is a GSC/HSC bus interface chip that sits between the
1151           PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1152           C110, J200, J210 and some D, K & R-class machines.  It's also
1153           used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1154           Say Y here if you have one of these machines or cards.
1155
1156 config SCSI_NCR_Q720
1157         tristate "NCR Quad 720 MCA SCSI support"
1158         depends on MCA && SCSI
1159         select SCSI_SPI_ATTRS
1160         help
1161           This is a driver for the MicroChannel Quad 720 card produced by
1162           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1163           tries to negotiate sync and uses tag command queueing.
1164
1165           Unless you have an NCR manufactured machine, the chances are that
1166           you do not have this SCSI card, so say N.
1167
1168 config SCSI_NCR53C8XX_DEFAULT_TAGS
1169         int "default tagged command queue depth"
1170         depends on SCSI_ZALON || SCSI_NCR_Q720
1171         default "8"
1172         ---help---
1173           "Tagged command queuing" is a feature of SCSI-2 which improves
1174           performance: the host adapter can send several SCSI commands to a
1175           device's queue even if previous commands haven't finished yet.
1176           Because the device is intelligent, it can optimize its operations
1177           (like head positioning) based on its own request queue. Some SCSI
1178           devices don't implement this properly; if you want to disable this
1179           feature, enter 0 or 1 here (it doesn't matter which).
1180
1181           The default value is 8 and should be supported by most hard disks.
1182           This value can be overridden from the boot command line using the
1183           'tags' option as follows (example):
1184           'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1185           4, set queue depth to 16 for target 2 and target 3 on controller 0
1186           and set queue depth to 10 for target 0 / lun 2 on controller 1.
1187
1188           The normal answer therefore is to go with the default 8 and to use
1189           a boot command line option for devices that need to use a different
1190           command queue depth.
1191
1192           There is no safe option other than using good SCSI devices.
1193
1194 config SCSI_NCR53C8XX_MAX_TAGS
1195         int "maximum number of queued commands"
1196         depends on SCSI_ZALON || SCSI_NCR_Q720
1197         default "32"
1198         ---help---
1199           This option allows you to specify the maximum number of commands
1200           that can be queued to any device, when tagged command queuing is
1201           possible. The default value is 32. Minimum is 2, maximum is 64.
1202           Modern hard disks are able to support 64 tags and even more, but
1203           do not seem to be faster when more than 32 tags are being used.
1204
1205           So, the normal answer here is to go with the default value 32 unless
1206           you are using very large hard disks with large cache (>= 1 MB) that
1207           are able to take advantage of more than 32 tagged commands.
1208
1209           There is no safe option and the default answer is recommended.
1210
1211 config SCSI_NCR53C8XX_SYNC
1212         int "synchronous transfers frequency in MHz"
1213         depends on SCSI_ZALON || SCSI_NCR_Q720
1214         default "20"
1215         ---help---
1216           The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1217           rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80.  The numbers
1218           are respectively the maximum data transfer rates in mega-transfers
1219           per second for each class.  For example, a FAST-20 Wide 16 device is
1220           able to transfer data at 20 million 16 bit packets per second for a
1221           total rate of 40 MB/s.
1222
1223           You may specify 0 if you want to only use asynchronous data
1224           transfers. This is the safest and slowest option. Otherwise, specify
1225           a value between 5 and 80, depending on the capability of your SCSI
1226           controller.  The higher the number, the faster the data transfer.
1227           Note that 80 should normally be ok since the driver decreases the
1228           value automatically according to the controller's capabilities.
1229
1230           Your answer to this question is ignored for controllers with NVRAM,
1231           since the driver will get this information from the user set-up.  It
1232           also can be overridden using a boot setup option, as follows
1233           (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1234           for FAST-20 synchronous data transfer (20 mega-transfers per
1235           second).
1236
1237           The normal answer therefore is not to go with the default but to
1238           select the maximum value 80 allowing the driver to use the maximum
1239           value supported by each controller. If this causes problems with
1240           your SCSI devices, you should come back and decrease the value.
1241
1242           There is no safe option other than using good cabling, right
1243           terminations and SCSI conformant devices.
1244
1245 config SCSI_NCR53C8XX_NO_DISCONNECT
1246         bool "not allow targets to disconnect"
1247         depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1248         help
1249           This option is only provided for safety if you suspect some SCSI
1250           device of yours to not support properly the target-disconnect
1251           feature. In that case, you would say Y here. In general however, to
1252           not allow targets to disconnect is not reasonable if there is more
1253           than 1 device on a SCSI bus. The normal answer therefore is N.
1254
1255 config SCSI_PAS16
1256         tristate "PAS16 SCSI support"
1257         depends on ISA && SCSI
1258         select SCSI_SPI_ATTRS
1259         ---help---
1260           This is support for a SCSI host adapter.  It is explained in section
1261           3.10 of the SCSI-HOWTO, available from
1262           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1263           of the box, you may have to change some settings in
1264           <file:drivers/scsi/pas16.h>.
1265
1266           To compile this driver as a module, choose M here: the
1267           module will be called pas16.
1268
1269 config SCSI_QLOGIC_FAS
1270         tristate "Qlogic FAS SCSI support"
1271         depends on ISA && SCSI
1272         ---help---
1273           This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1274           FastSCSI! cards as well as any other card based on the FASXX chip
1275           (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1276
1277           This driver does NOT support the PCI versions of these cards. The
1278           PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1279           SCSI support"), below.
1280
1281           Information about this driver is contained in
1282           <file:Documentation/scsi/qlogicfas.txt>.  You should also read the
1283           SCSI-HOWTO, available from
1284           <http://www.tldp.org/docs.html#howto>.
1285
1286           To compile this driver as a module, choose M here: the
1287           module will be called qlogicfas.
1288
1289 config SCSI_QLOGIC_FC_FIRMWARE
1290         bool "Include loadable firmware in driver"
1291         depends on SCSI_QLOGIC_FC
1292         help
1293           Say Y to include ISP2X00 Fabric Initiator/Target Firmware, with
1294           expanded LUN addressing and FcTape (FCP-2) support, in the
1295           qlogicfc driver. This is required on some platforms.
1296
1297 config SCSI_QLOGIC_1280
1298         tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1299         depends on PCI && SCSI
1300         help
1301           Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1302
1303           To compile this driver as a module, choose M here: the
1304           module will be called qla1280.
1305
1306 config SCSI_QLOGICPTI
1307         tristate "PTI Qlogic, ISP Driver"
1308         depends on SBUS && SCSI
1309         help
1310           This driver supports SBUS SCSI controllers from PTI or QLogic. These
1311           controllers are known under Solaris as qpti and in the openprom as
1312           PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1313           driven by a different driver.
1314
1315           To compile this driver as a module, choose M here: the
1316           module will be called qlogicpti.
1317
1318 source "drivers/scsi/qla2xxx/Kconfig"
1319 source "drivers/scsi/qla4xxx/Kconfig"
1320
1321 config SCSI_LPFC
1322         tristate "Emulex LightPulse Fibre Channel Support"
1323         depends on PCI && SCSI
1324         select SCSI_FC_ATTRS
1325         help
1326           This lpfc driver supports the Emulex LightPulse
1327           Family of Fibre Channel PCI host adapters.
1328
1329 config SCSI_SIM710
1330         tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1331         depends on (EISA || MCA) && SCSI
1332         select SCSI_SPI_ATTRS
1333         ---help---
1334           This driver for NCR53c710 based SCSI host adapters.
1335
1336           It currently supports Compaq EISA cards and NCR MCA cards
1337
1338 config SCSI_SYM53C416
1339         tristate "Symbios 53c416 SCSI support"
1340         depends on ISA && SCSI
1341         ---help---
1342           This is support for the sym53c416 SCSI host adapter, the SCSI
1343           adapter that comes with some HP scanners. This driver requires that
1344           the sym53c416 is configured first using some sort of PnP
1345           configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1346           are using isapnp then you need to compile this driver as a module
1347           and then load it using insmod after isapnp has run. The parameters
1348           of the configured card(s) should be passed to the driver. The format
1349           is:
1350
1351           insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1352
1353           To compile this driver as a module, choose M here: the
1354           module will be called sym53c416.
1355
1356 config SCSI_DC395x
1357         tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
1358         depends on PCI && SCSI && EXPERIMENTAL
1359         ---help---
1360           This driver supports PCI SCSI host adapters based on the ASIC
1361           TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1362
1363           This driver works, but is still in experimental status. So better
1364           have a bootable disk and a backup in case of emergency.
1365
1366           Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1367
1368           To compile this driver as a module, choose M here: the
1369           module will be called dc395x.
1370
1371 config SCSI_DC390T
1372         tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1373         depends on PCI && SCSI
1374         ---help---
1375           This driver supports PCI SCSI host adapters based on the Am53C974A
1376           chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1377           PCscsi/PCnet (Am53/79C974) solutions.
1378
1379           Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1380
1381           Note that this driver does NOT support Tekram DC390W/U/F, which are
1382           based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1383
1384           To compile this driver as a module, choose M here: the
1385           module will be called tmscsim.
1386
1387 config SCSI_T128
1388         tristate "Trantor T128/T128F/T228 SCSI support"
1389         depends on ISA && SCSI
1390         select SCSI_SPI_ATTRS
1391         select CHECK_SIGNATURE
1392         ---help---
1393           This is support for a SCSI host adapter. It is explained in section
1394           3.11 of the SCSI-HOWTO, available from
1395           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1396           of the box, you may have to change some settings in
1397           <file:drivers/scsi/t128.h>.  Note that Trantor was purchased by
1398           Adaptec, and some former Trantor products are being sold under the
1399           Adaptec name.
1400
1401           To compile this driver as a module, choose M here: the
1402           module will be called t128.
1403
1404 config SCSI_U14_34F
1405         tristate "UltraStor 14F/34F support"
1406         depends on ISA && SCSI && ISA_DMA_API
1407         ---help---
1408           This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1409           The source at <file:drivers/scsi/u14-34f.c> contains some
1410           information about this hardware.  If the driver doesn't work out of
1411           the box, you may have to change some settings in
1412           <file: drivers/scsi/u14-34f.c>.  Read the SCSI-HOWTO, available from
1413           <http://www.tldp.org/docs.html#howto>.  Note that there is also
1414           another driver for the same hardware: "UltraStor SCSI support",
1415           below.  You should say Y to both only if you want 24F support as
1416           well.
1417
1418           To compile this driver as a module, choose M here: the
1419           module will be called u14-34f.
1420
1421 config SCSI_U14_34F_TAGGED_QUEUE
1422         bool "enable tagged command queueing"
1423         depends on SCSI_U14_34F
1424         help
1425           This is a feature of SCSI-2 which improves performance: the host
1426           adapter can send several SCSI commands to a device's queue even if
1427           previous commands haven't finished yet.
1428           This is equivalent to the "u14-34f=tc:y" boot option.
1429
1430 config SCSI_U14_34F_LINKED_COMMANDS
1431         bool "enable elevator sorting"
1432         depends on SCSI_U14_34F
1433         help
1434           This option enables elevator sorting for all probed SCSI disks and
1435           CD-ROMs. It definitely reduces the average seek distance when doing
1436           random seeks, but this does not necessarily result in a noticeable
1437           performance improvement: your mileage may vary...
1438           This is equivalent to the "u14-34f=lc:y" boot option.
1439
1440 config SCSI_U14_34F_MAX_TAGS
1441         int "maximum number of queued commands"
1442         depends on SCSI_U14_34F
1443         default "8"
1444         help
1445           This specifies how many SCSI commands can be maximally queued for
1446           each probed SCSI device. You should reduce the default value of 8
1447           only if you have disks with buggy or limited tagged command support.
1448           Minimum is 2 and maximum is 14. This value is also the window size
1449           used by the elevator sorting option above. The effective value used
1450           by the driver for each probed SCSI device is reported at boot time.
1451           This is equivalent to the "u14-34f=mq:8" boot option.
1452
1453 config SCSI_ULTRASTOR
1454         tristate "UltraStor SCSI support"
1455         depends on X86 && ISA && SCSI
1456         ---help---
1457           This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1458           adapter family.  This driver is explained in section 3.12 of the
1459           SCSI-HOWTO, available from
1460           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1461           of the box, you may have to change some settings in
1462           <file:drivers/scsi/ultrastor.h>.
1463
1464           Note that there is also another driver for the same hardware:
1465           "UltraStor 14F/34F support", above.
1466
1467           To compile this driver as a module, choose M here: the
1468           module will be called ultrastor.
1469
1470 config SCSI_NSP32
1471         tristate "Workbit NinjaSCSI-32Bi/UDE support"
1472         depends on PCI && SCSI && !64BIT
1473         help
1474           This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1475           SCSI host adapter. Please read the SCSI-HOWTO, available from
1476           <http://www.tldp.org/docs.html#howto>.
1477
1478           To compile this driver as a module, choose M here: the
1479           module will be called nsp32.
1480
1481 config SCSI_DEBUG
1482         tristate "SCSI debugging host simulator"
1483         depends on SCSI
1484         help
1485           This is a host adapter simulator that can simulate multiple hosts
1486           each with multiple dummy SCSI devices (disks). It defaults to one
1487           host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1488           RAM as storage (i.e. it is a ramdisk). To save space when multiple
1489           dummy disks are simulated, they share the same kernel RAM for 
1490           their storage. See <http://www.torque.net/sg/sdebug.html> for more
1491           information. This driver is primarily of use to those testing the
1492           SCSI and block subsystems. If unsure, say N.
1493
1494 config SCSI_MESH
1495         tristate "MESH (Power Mac internal SCSI) support"
1496         depends on PPC32 && PPC_PMAC && SCSI
1497         help
1498           Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1499           SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1500           other Power Macintoshes do). Say Y to include support for this SCSI
1501           adaptor.
1502
1503           To compile this driver as a module, choose M here: the
1504           module will be called mesh.
1505
1506 config SCSI_MESH_SYNC_RATE
1507         int "maximum synchronous transfer rate (MB/s) (0 = async)"
1508         depends on SCSI_MESH
1509         default "5"
1510         help
1511           On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1512           drives a bus which is entirely internal to the machine (such as the
1513           7500, 7600, 8500, etc.), the MESH is capable of synchronous
1514           operation at up to 10 MB/s. On machines where the SCSI bus
1515           controlled by the MESH can have external devices connected, it is
1516           usually rated at 5 MB/s. 5 is a safe value here unless you know the
1517           MESH SCSI bus is internal only; in that case you can say 10. Say 0
1518           to disable synchronous operation.
1519
1520 config SCSI_MESH_RESET_DELAY_MS
1521         int "initial bus reset delay (ms) (0 = no reset)"
1522         depends on SCSI_MESH
1523         default "4000"
1524
1525 config SCSI_MAC53C94
1526         tristate "53C94 (Power Mac external SCSI) support"
1527         depends on PPC32 && PPC_PMAC && SCSI
1528         help
1529           On Power Macintoshes (and clones) with two SCSI buses, the external
1530           SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1531           machines which only have one SCSI bus, such as the 7200, also use
1532           the 53C94. Say Y to include support for the 53C94.
1533
1534           To compile this driver as a module, choose M here: the
1535           module will be called mac53c94.
1536
1537 source "drivers/scsi/arm/Kconfig"
1538
1539 config JAZZ_ESP
1540         bool "MIPS JAZZ FAS216 SCSI support"
1541         depends on MACH_JAZZ && SCSI
1542         select SCSI_SPI_ATTRS
1543         help
1544           This is the driver for the onboard SCSI host adapter of MIPS Magnum
1545           4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1546           systems.
1547
1548 config A3000_SCSI
1549         tristate "A3000 WD33C93A support"
1550         depends on AMIGA && SCSI
1551         help
1552           If you have an Amiga 3000 and have SCSI devices connected to the
1553           built-in SCSI controller, say Y. Otherwise, say N.
1554
1555           To compile this driver as a module, choose M here: the
1556           module will be called a3000.
1557
1558 config A2091_SCSI
1559         tristate "A2091/A590 WD33C93A support"
1560         depends on ZORRO && SCSI
1561         help
1562           If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1563           say N.
1564
1565           To compile this driver as a module, choose M here: the
1566           module will be called a2091.
1567
1568 config GVP11_SCSI
1569         tristate "GVP Series II WD33C93A support"
1570         depends on ZORRO && SCSI
1571         ---help---
1572           If you have a Great Valley Products Series II SCSI controller,
1573           answer Y. Also say Y if you have a later model of GVP SCSI
1574           controller (such as the GVP A4008 or a Combo board). Otherwise,
1575           answer N. This driver does NOT work for the T-Rex series of
1576           accelerators from TekMagic and GVP-M.
1577
1578           To compile this driver as a module, choose M here: the
1579           module will be called gvp11.
1580
1581 config CYBERSTORM_SCSI
1582         tristate "CyberStorm SCSI support"
1583         depends on ZORRO && SCSI
1584         help
1585           If you have an Amiga with an original (MkI) Phase5 Cyberstorm
1586           accelerator board and the optional Cyberstorm SCSI controller,
1587           answer Y. Otherwise, say N.
1588
1589 config CYBERSTORMII_SCSI
1590         tristate "CyberStorm Mk II SCSI support"
1591         depends on ZORRO && SCSI
1592         help
1593           If you have an Amiga with a Phase5 Cyberstorm MkII accelerator board
1594           and the optional Cyberstorm SCSI controller, say Y. Otherwise,
1595           answer N.
1596
1597 config BLZ2060_SCSI
1598         tristate "Blizzard 2060 SCSI support"
1599         depends on ZORRO && SCSI
1600         help
1601           If you have an Amiga with a Phase5 Blizzard 2060 accelerator board
1602           and want to use the onboard SCSI controller, say Y. Otherwise,
1603           answer N.
1604
1605 config BLZ1230_SCSI
1606         tristate "Blizzard 1230IV/1260 SCSI support"
1607         depends on ZORRO && SCSI
1608         help
1609           If you have an Amiga 1200 with a Phase5 Blizzard 1230IV or Blizzard
1610           1260 accelerator, and the optional SCSI module, say Y. Otherwise,
1611           say N.
1612
1613 config FASTLANE_SCSI
1614         tristate "Fastlane SCSI support"
1615         depends on ZORRO && SCSI
1616         help
1617           If you have the Phase5 Fastlane Z3 SCSI controller, or plan to use
1618           one in the near future, say Y to this question. Otherwise, say N.
1619
1620 config SCSI_A4000T
1621         tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
1622         depends on AMIGA && SCSI && EXPERIMENTAL
1623         select SCSI_SPI_ATTRS
1624         help
1625           If you have an Amiga 4000T and have SCSI devices connected to the
1626           built-in SCSI controller, say Y. Otherwise, say N.
1627
1628           To compile this driver as a module, choose M here: the
1629           module will be called a4000t.
1630
1631 config SCSI_ZORRO7XX
1632         tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
1633         depends on ZORRO && SCSI && EXPERIMENTAL
1634         select SCSI_SPI_ATTRS
1635         help
1636           Support for various NCR53c710-based SCSI controllers on Zorro
1637           expansion boards for the Amiga.
1638           This includes:
1639             - the Amiga 4091 Zorro III SCSI-2 controller,
1640             - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1641               (info at
1642               <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1643             - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1644               accelerator card for the Amiga 1200,
1645             - the SCSI controller on the GVP Turbo 040/060 accelerator.
1646
1647 config OKTAGON_SCSI
1648         tristate "BSC Oktagon SCSI support (EXPERIMENTAL)"
1649         depends on ZORRO && SCSI && EXPERIMENTAL
1650         help
1651           If you have the BSC Oktagon SCSI disk controller for the Amiga, say
1652           Y to this question.  If you're in doubt about whether you have one,
1653           see the picture at
1654           <http://amiga.resource.cx/exp/search.pl?product=oktagon>.
1655
1656 config ATARI_SCSI
1657         tristate "Atari native SCSI support"
1658         depends on ATARI && SCSI
1659         select SCSI_SPI_ATTRS
1660         ---help---
1661           If you have an Atari with built-in NCR5380 SCSI controller (TT,
1662           Falcon, ...) say Y to get it supported. Of course also, if you have
1663           a compatible SCSI controller (e.g. for Medusa).
1664
1665           To compile this driver as a module, choose M here: the
1666           module will be called atari_scsi.
1667
1668           This driver supports both styles of NCR integration into the
1669           system: the TT style (separate DMA), and the Falcon style (via
1670           ST-DMA, replacing ACSI).  It does NOT support other schemes, like
1671           in the Hades (without DMA).
1672
1673 config ATARI_SCSI_TOSHIBA_DELAY
1674         bool "Long delays for Toshiba CD-ROMs"
1675         depends on ATARI_SCSI
1676         help
1677           This option increases the delay after a SCSI arbitration to
1678           accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1679           use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1680           would impact performance a bit, so say N.
1681
1682 config ATARI_SCSI_RESET_BOOT
1683         bool "Reset SCSI-devices at boottime"
1684         depends on ATARI_SCSI
1685         help
1686           Reset the devices on your Atari whenever it boots.  This makes the
1687           boot process fractionally longer but may assist recovery from errors
1688           that leave the devices with SCSI operations partway completed.
1689
1690 config TT_DMA_EMUL
1691         bool "Hades SCSI DMA emulator"
1692         depends on ATARI_SCSI && HADES
1693         help
1694           This option enables code which emulates the TT SCSI DMA chip on the
1695           Hades. This increases the SCSI transfer rates at least ten times
1696           compared to PIO transfers.
1697
1698 config MAC_SCSI
1699         bool "Macintosh NCR5380 SCSI"
1700         depends on MAC && SCSI=y
1701         select SCSI_SPI_ATTRS
1702         help
1703           This is the NCR 5380 SCSI controller included on most of the 68030
1704           based Macintoshes.  If you have one of these say Y and read the
1705           SCSI-HOWTO, available from
1706           <http://www.tldp.org/docs.html#howto>.
1707
1708 config SCSI_MAC_ESP
1709         tristate "Macintosh NCR53c9[46] SCSI"
1710         depends on MAC && SCSI
1711         help
1712           This is the NCR 53c9x SCSI controller found on most of the 68040
1713           based Macintoshes.  If you have one of these say Y and read the
1714           SCSI-HOWTO, available from
1715           <http://www.tldp.org/docs.html#howto>.
1716
1717           To compile this driver as a module, choose M here: the
1718           module will be called mac_esp.
1719
1720 config MVME147_SCSI
1721         bool "WD33C93 SCSI driver for MVME147"
1722         depends on MVME147 && SCSI=y
1723         select SCSI_SPI_ATTRS
1724         help
1725           Support for the on-board SCSI controller on the Motorola MVME147
1726           single-board computer.
1727
1728 config MVME16x_SCSI
1729         tristate "NCR53C710 SCSI driver for MVME16x"
1730         depends on MVME16x && SCSI
1731         select SCSI_SPI_ATTRS
1732         help
1733           The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1734           SCSI controller chip.  Almost everyone using one of these boards
1735           will want to say Y to this question.
1736
1737 config BVME6000_SCSI
1738         tristate "NCR53C710 SCSI driver for BVME6000"
1739         depends on BVME6000 && SCSI
1740         select SCSI_SPI_ATTRS
1741         help
1742           The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1743           SCSI controller chip.  Almost everyone using one of these boards
1744           will want to say Y to this question.
1745
1746 config SUN3_SCSI
1747         tristate "Sun3 NCR5380 SCSI"
1748         depends on SUN3 && SCSI
1749         select SCSI_SPI_ATTRS
1750         help
1751           This option will enable support for the OBIO (onboard io) NCR5380
1752           SCSI controller found in the Sun 3/50 and 3/60, as well as for
1753           "Sun3" type VME scsi controllers also based on the NCR5380.
1754           General Linux information on the Sun 3 series (now discontinued)
1755           is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1756
1757 config SUN3X_ESP
1758         bool "Sun3x ESP SCSI"
1759         depends on SUN3X && SCSI=y
1760         select SCSI_SPI_ATTRS
1761         help
1762           The ESP was an on-board SCSI controller used on Sun 3/80
1763           machines.  Say Y here to compile in support for it.
1764
1765 config SCSI_SUNESP
1766         tristate "Sparc ESP Scsi Driver"
1767         depends on SBUS && SCSI
1768         select SCSI_SPI_ATTRS
1769         help
1770           This is the driver for the Sun ESP SCSI host adapter. The ESP
1771           chipset is present in most SPARC SBUS-based computers.
1772
1773           To compile this driver as a module, choose M here: the
1774           module will be called esp.
1775
1776 config ZFCP
1777         tristate "FCP host bus adapter driver for IBM eServer zSeries"
1778         depends on S390 && QDIO && SCSI
1779         select SCSI_FC_ATTRS
1780         help
1781           If you want to access SCSI devices attached to your IBM eServer
1782           zSeries by means of Fibre Channel interfaces say Y.
1783           For details please refer to the documentation provided by IBM at
1784           <http://oss.software.ibm.com/developerworks/opensource/linux390>
1785
1786           This driver is also available as a module. This module will be
1787           called zfcp. If you want to compile it as a module, say M here
1788           and read <file:Documentation/kbuild/modules.txt>.
1789
1790 config SCSI_SRP
1791         tristate "SCSI RDMA Protocol helper library"
1792         depends on SCSI && PCI
1793         select SCSI_TGT
1794         help
1795           If you wish to use SRP target drivers, say Y.
1796
1797           To compile this driver as a module, choose M here: the
1798           module will be called libsrp.
1799
1800 endif # SCSI_LOWLEVEL
1801